TM 11-5820-890-10-3
CLEARING FH DATA
This procedure allows you to clear FH data from your RT.
NOTE
You can't clear the channel you're operating on.
NCS will direct which channels and data to clear.
a.
Set FCTN to LD.
b.
Set MODE to FH.
c.
Press CLR followed by the number of the channel that contains the data you wish to clear. Display changes as
shown; a beep is heard.
d.
Press CLR followed by L; then press the left digit of the data you wish to clear (18). Display changes as shown; a
beep is heard.
e.
Set RT switches to normal operating positions.
2-38