POCKET GUIDE
TM 11-5820-890-10-6
PRIMARY TASK 1: Load Single Channel Freq in SINCGARS RT
SUBTASKS
ACTION
RESULTS
a. Prepare to
(1) Obtain proper freqs from
(Load CUE freq only if directed)
perform task
ANCD*
(2) Set RT controls COMSEC to
PT MODE to SC FCTN to Z-
FH, TST, and then to LD
CHAN to MAN, CUE, or 1-6
RT display shown [GOOD] (or
see unit maintainer)
b. Load SC
(1) Press:
Freq
FREQ
Display shows [00000] or
[30000]
CLR
Display shows [ _ _ _ _ _ ]
XXXXX (Freq)
Display shows SC freq entered
STO
Display blinks (data is stored)
(2) Repeat Step b-1 for each
(As directed by NCS or unit
freq needed
SOP)
(3) Set
Loading of SC freq is
FCTN to SQ ON
complete
*In units using secure, FH nets, operators normally load on a routine basis only a
MANSC frequency. CUE and CHAN 1-6 SC frequencies are loaded only as needed or
directed
**Only NCS and Alt NCS routinely load a CUE frequency
***RT settings for RT-1523E are set via MENU
11