Home
Download PDF
Order CD-ROM
Order in Print
SECTION I. GENERAL INFORMATION
REPORTING EQUIPMENT IMPROVEMENT RECOMMENDATIONS (EIR)
SECTION II. EQUIPMENT DESCRIPTION
DIFFERENCES BETWEEN MODELS
PERFORMANCE
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS
VEHICULAR RADIOS
1. VEHICULAR ANTENNA - TM-11-5820-890-10-1_21
LONG RANGE (LR) Mounted in Mounting Adapter (AN/VRC-90A)
2. POWER AMPLIFIER
LONG RANGE/SHORT RANGE (LR/SR) (AN/VRC-89A OR AN/VRC-91A); LONG RANGE/LONG RANGE (LR/LR) (AN/VRC-92A)
3. POWER AMPLIFIER MOUNT - TM-11-5820-890-10-1_25
MAJOR COMPONENTS USED WITH RADIO SETS - TM-11-5820-890-10-1_26
SECTION Ill. TECHNICAL PRINCIPLES OF OPERATION
CUE FREQUENCY
COMSEC KEYS
CHAPTER 2 OPERATORS INSTRUCTIONS
RECEIVER-TRANSMITTER
COMSEC switch.
CHAN (channel) switch.
SIG (signal) display.
Keyboard
CLR (clear) button
AUD/FILL and AUD/DATA Connectors
Retransmit RT Connected to Retransmit RT
Battery Box and RT Systems Connector
Loudspeaker-Control Unit
ECCM fill device - TM-11-5820-890-10-1_42
Mounting Adapter - TM-11-5820-890-10-1_43
12. Indicator lamp and lens
1. Power Supply Adapter
SECTION II. ASSEMBLY AND PREPARATION FOR USE
INSTALLATION OF PRIMARY BATTERY AND BATTERY BOX
ANTENNA - TM-11-5820-890-10-1_48
HANDSET - TM-11-5820-890-10-1_49
VEHICULAR RADIO ASSEMBLY - TM-11-5820-890-10-1_50
Mounting and Dismounting RT From Mounting Adapter
Mounting and Dismounting RT Mounted in a Power Supply Adapter
MOUNTING RT
CABLING
SR/LR Cabling (in mounting adapter)
LR CABLING (IN MOUNTING ADAPTER) - TM-11-5820-890-10-1_56
LR/LR Cabling (in mounting adapter)
STAY-DOWN CLAMP
STAY-DOWN CLIP
CHECKING AND SETTING LIFE CONDITION OF PRIMARY BATTERY - TM-11-5820-890-10-1_60
Battery Life Indicator Readings and Remaining Hours (BA-5590/U Lithium Battery)
PRE-MISSION CHECK - TM-11-5820-890-10-1_62
SECTION III. SINGLE CHANNEL OPERATING PROCEDURES
CLEARING SC FREQUENCIES
SECTION IV. FREQUENCY HOPPING OPERATING PROCEDURES
LOADING FH DATA.
Clearing FH data - TM-11-5820-890-10-1_67
LOADING COMSEC KEYS (LOCAL FILL)
BASIC COMSEC PROCEDURES
PRE-MISSION CHECK - TM-11-5820-890-10-1_70
NET OPENING
a. Upon NCS net opening alert
g. Press STO to store the ERF
FH Update Using ERF
CUE
CUE AND ERF
JAMMING AND ANTIJAMMING - TM-11-5820-890-10-1_77
SINGLE CHANNEL OPERATION
FREQUENCY HOPPING OPERATION
FREQUENCY HOPPING OPERATION, Cont
SECTION V. OPERATOR TROUBLESHOOTING
CHAPTER 3 NCS PROCEDURES
3. Hopset data
LOCALL FILLS
HOPSET - TM-11-5820-890-10-1_88
Cold Start TSK
LOADING FH SYNC TIME BY ERF
CHECKING FH SYNC TIME
NCS NOTES - TM-11-5820-890-10-1_92
SUMMARY OF COLD START NET OPENING PROCEDURE
COLD START NET OPENING - TM-11-5820-890-10-1_94
d. Set CHAN to MAN
i. After transmitting ERF
SECTION II. ADDITIONAL NCS PROCEDURES
BRINGING ANOTHER STATION INTO THE NET - TM-11-5820-890-10-1_98
CHANGING HOPSET IDENTIFICATION (ID)
MONITORING FH SYNC TIME OF OTHER FH NETS
REMOTE FILL OF COMSEC KEY
JAMMING AND ANTIJAMMING - TM-11-5820-890-10-1_102
SECTION III. NCS NET TROUBLESHOOTING
CHAPTER 4 OTHER OPERATING PROCEDURES
OPERATORS CONTROLS, INDICATORS, AND CONNECTORS
OPERATIONAL NOTES
INTERCOM (ICM) OPERATION - TM-11-5820-890-10-1_107
RCU CABLING
RT in Manpack, RCU in Vehicular Mounting Adapter
RT in Vehicular Mounting Adapter, RCU in Manpack
RT in Manpack, RCU in Manpack
SECTION II. CONTROL-MONITOR (CM)
INITIAL SET-UP AND SELF-TEST
SETTlNG AND CHANGING RT FUNCTIONS
CM CABLING
SECTION Ill. ECCM FILL DEVICE
LOADING FILL DEVICE USING ANOTHER FILL DEVICE
SECTION IV. OPERATION WITH EXTERNAL EQUIPMENT
OPERATION WITH EXTERNAL EQUIPMENT
OPERATION WITH EXTERNAL EQUIPMENT Cont
MOUNTING ADAPTER WITH ONE OR TWO RT/RCU
Main Junction Box
WIRE LINE ADAPTER, HYX-57/TSEC
SECTION V. ADDITIONAL OPERATING PROCEDURES
SC to FH retransmit operation (mixed mode) - TM-11-5820-890-10-1_125
ERF relay operation - TM-11-5820-890-10-1_126
ALTERNATE ANTENNA CONFIGURATION
Scanning - TM-11-5820-890-10-1_128
BATTERY TRAY
SECTION VI. OPERATION UNDER UNUSUAL CONDITIONS
EMERGENCY PROCEDURES Cont
MANPACK BATTERY NEAR END OF ITS LIFE
UNUSUAL WEATHER
CHAPTER 5 MAINTENANCE INSTRUCTIONS
SPECIAL INSTRUCTIONS - TM-11-5820-890-10-1_135
BATTERY PHYSICAL CONDITION
RECEIVER-TRANSMlTTER SELF-TEST
TRANSMITTER - TM-11-5820-890-10-1_138
REMOTE OPERATION
CONTROL-MONITOR RT FUNCTION CONTROL
CABLES
SECTION II. TROUBLESHOOTING PROCEDURES
TROUBLESHOOTING TABLE
TROUBLESHOOTlNG PROCEDURES
RADIO. Sig display
RADIO. Handset - TM-11-5820-890-10-1_146
RADIO. Displays - TM-11-5820-890-10-1_147
CONTROL-MONITOR. Input/output circuit
CONTROL MONITOR. Displays
SECTION III. OPERATOR MAINTENANCE
CAUTION/WARNING LABELS AND PLATES
APPENDIX A REFERENCES - TM-11-5820-890-10-1_152
JULIAN DATE CALENDAR
TIME ZONE MAP - TM-11-5820-890-10-1_154
OPERATOR ROAD MAP - TM-11-5820-890-10-1_155
FLOW CHARTS TASK 1: SC FREQUENCIES
FLOW CHARTS TASK 2. LOCAL FILLS
FLOW CHARTS TASK 2: LOCAL FILLS
FLOW CHARTS TASK 3: NET OPENING
FLOW CHARTS TASK 3: NET OPENING
FLOW CHARTS TASK 4: COMMUNICATE IN FH NET
FLOW CHARTS TASK 5: MAINTAIN NET - TM-11-5820-890-10-1_162
FLOW CHARTS TASK 5: MAINTAIN NET - TM-11-5820-890-10-1_163
APPENDIX B COMPONENTS OF END ITEM AND BASIC ISSUE ITEMS LISTS
SECTION II. COMPONENTS OF END ITEM
SECTION II. COMPONENTS OF END ITEM -CONT
National Stock Number - TM-11-5820-890-10-1_167
National Stock Number - TM-11-5820-890-10-1_168
National Stock Number - TM-11-5820-890-10-1_169
National Stock Number - TM-11-5820-890-10-1_170
National Stock Number - TM-11-5820-890-10-1_171
SECTION III. BASIC ISSUE ITEMS
National Stock Number - TM-11-5820-890-10-1_173
APPENDIX C ADDITIONAL AUTHORIZATION LIST
Description and Part Number
APPENDIX E REFERENCE DATA
ABBREVIATIONS - TM-11-5820-890-10-1_177
ABBREVIATIONS -cont - TM-11-5820-890-10-1_178
ABBREVIATIONS -cont - TM-11-5820-890-10-1_179
GLOSSARY
GLOSSARY -cont - TM-11-5820-890-10-1_181
INDEX - TM-11-5820-890-10-1_182
INDEX -cont - TM-11-5820-890-10-1_183
INDEX -cont - TM-11-5820-890-10-1_184
INDEX -cont - TM-11-5820-890-10-1_185
INDEX -cont - TM-11-5820-890-10-1_186
INDEX -cont - TM-11-5820-890-10-1_187
INDEX -cont - TM-11-5820-890-10-1_188
INDEX -cont - TM-11-5820-890-10-1_189
INDEX -cont - TM-11-5820-890-10-1_190
INDEX -cont - TM-11-5820-890-10-1_191
INDEX -cont - TM-11-5820-890-10-1_192
INDEX -cont - TM-11-5820-890-10-1_193