TM 11-5820-890-20-1
4.1.
TROUBLESHOOTING CABLES. Continued
(2)
Short to Ground Test Procedure:
(a)
Disconnect cable from system being checked.
(b)
Set Multimeter (1) for continuity check (highest ohm range).
(c)
Connect one test lead (2) to each pin, of connector (3), one at a time.
(d)
Connect other test lead to outer casing of connector (see Cable Schematics for details).
(e)
Cable is good if Multimeter reads INFINITY/open. Cable may be defective and must be replaced if
Multimeter reads other than INFINITY/open.
(f)
Repeat steps (c) and (d) until all pins have been checked.
(3)
Short Pin to Pin Test Procedure:
(a)
Disconnect cable from system being checked.
(b)
Set Multimeter (1) for continuity check (highest ohm range).
(c)
Connect one test lead (2) to each pin, of connector (3), one at a time.
(d)
Connect other test lead to another pin.
(e)
Cable is good if Multimeter reads INFINITY/open. Cable may be defective if reading is other than
INFINITY/open (see Cable Schematics); if pins are not connected, replace cable.
(9
Repeat steps (c) and (d) until all pins have been checked.
4 - 2