TM 11-5820-890-20-13.1.OPERATIONAL CHECK. ContinuedSTEP 3. RT SELF-TEST:STEPS TO PERFORM3.1Set RTCOMSEC to CTFCTN to TST3.2 Set RT:FCTN to LDCHAN to MANDATA to OFF3.3Press PTT twiceExternal devices (LS 671 Speaker)STEP 4. LOAD CHECKS:CHECKS TO MAKEN/ART display reads FAIL 6?RT passes self-test?RT now passes self-test?N/AN/ART display reads 30000?COMSEC alarm heard atHS/loudspeaker?(For RT-1523/A/B/D)Steady tone heard atHS/loudspeaker?*(For RT-15230Steady tone is heardACTIONS TO TAKEN/ANO:Continue 1YES:Go to TS Chart 8YES:Go to Step 3.2NO:Disconnect all cables fromfront of RT; rerun self-testYES:Reconnect all cables to frontof RT and go to Step 3.2NO: Replace RTN/AN/AYES: Continue 1NO:Replace RTYES:Go to Step 3.3NO:If no external devices,go to TS Chart 9NO:If using external devices,go to TS Chart 10YES:Go to STEP 4NO:If no external devices,go to TS Chart 9NO:If using external devices,go to TS Chart 10YES:Go to STEP 4NO:If no external devices,go to TS Chart 9NO:If using external devices,go to TS Chart 10STEPS TO PERFORMCHECKS TO MAKE4.1Load RT with SC frequencies:SC frequencies load properly?Chan 1:41000Chan 2:54000Chan 3:750004.2Set RT MODE to FH and loadRT accepts fill?RT with COMSEC and FH data*Go to TM 10-6 page 7, Task 2.4.3Load test sync time (82/09:36)Test sync time loads properly?4.4Set RT to STBYRT shuts down properly?ACTIONS TO TAKEYES:Go to Step 4.2NO: Replace RTYES:Go to Step 4.3NO:Go to TS Chart 11YES:Go to Step 4.4NO:Replace RTYES:Go to Step 4.5NO: Replace RT3 - 4