TM 11-5820-890-30-44-21. REPLACEMENT OF CONNECTOR J9. ContinuedITEMACTIONREMARKSINSTALLATIONe.f.g.Connector J9 (9)Protective cap (12)Access cover (2)Using solder kit, solder tagged wires tocorrect pins of replacement connectorJ9. Remove wire tags. Slide insulator oversolder connections. Assemble connector.Apply silicone compound to connectorthreads and o-ring before installation.Install o-ring and connector in chassis.Position retained protective cap retainer(10) and replacement nut (11) to connec-tor. Using torque wrench and 7/8-inchsocket, torque nut to 58 to 62 in-lb.Install retained protective cap (12) onconnector J9 (9).Install.Before and after soldering,clean wires and pins withalcohol and cotton swabs.This was removed instep c.See figure 4-5. This wasremoved in step b.Refer to paragraph 4-19 foraccess cover installationprocedures.4-22.Tools:REPLACEMENT OF CONNECTORS J2 - J6.Soldering kitTorque wrench3/4-inch spanner wrenchFlat tip screwdriverSpanner attachmentTorque screwdriverSocket wrenchExpendable Supplies:Silicone compoundSolderAlcoholCotton swabsReferences:Paragraph 4-19 for removal and installation of audio amplifier CCA.ITEMACTIONREMARKSREMOVALa. Mounting adapterSet on work surface with right sidetoward you.b. Access cover (2)Remove.c. Audio amplifier CCA (6)Remove.d. Protective cap (3)Remove from defective connector J2, J3,J4, J5, or J6 (1).See figure 4-5. Refer toparagraph 4-19 for accesscover removal procedures.Refer to paragraph 4-19for removal procedures.See figure 4-8.4-107