TM 11-5820-890-30-412-23. OPERATIONAL CHECK. ContinuedStep 9. TRANSMIT DIGITAL DATA TEST. ContinuedActionSet test adapter:PTT: OFF.Set REF RT and RCU:COMSEC:Set test adapter:PTT: UUT.Set test adapter:PTT: OFF.Disconnect WI cable from RF SignalGenerator FM I/O connector and connectto Function Generator MOD OUT connector,Connect unconnected WI cable fromFunction Generator FCTN OUT connectorto RF Signal Generator FM I/O connector.ResponseScope is locked-up on CH 1 at samefrequency as CH 2. If not, go to chart 35.No response.No response.No response.Step 10. RECEIVE DIGITAL DATA TEST.SET:REF RRTEST ADAPTER:FUNCTlON GENERATOR:.RF SIGNAL GENERATOR:FCTN: REMRESPONSE: 1TRIGGER: CONTFM DEVIATION: 4 to 5 kHzActiona. Adjust fine frequency control on FunctionGenerator until scope CH 1 is locked-up.b. Disconnect W1 cable from RF SignalGenerator FM I/O connector.Responsea. Adjustment is successful and scope islocked-up on CH 1 at same frequency asCH 2. If not, go to chart 36.b. No response.12-39