TM 11-5820-890-10-1
LOCKOUT SET. Loading Lockout Set (local fill). Check the SOI for required lockout
set(s).
CAUTION
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.
DO NOT CONNECT FILL DEVICE DIRECTLY TO RADIO AUD/FILL CON-
NECTOR. CONNECTOR DAMAGE MAY OCCUR IF FILL CABLE IS NOT
USED.
Make sure that the ECCM fill device is loaded. If the ECCM fill device
to be filled, see Chapter 4.
Check to see if the lockout set(s) have already been loaded in RT:
Set RT FCTN to SQ ON, RT MODE to FH (if NCS, set MODE to
CHAN
to channel where hopset is stored; then press RT FREQ several times. Watch
display for lockout set numbers.
needs
Set ECCM fill device function switch to OFF.
Connect ECCM fill device to RT connector AUD/FILL using fill cable.
Set RT FCTN to LD.
Set RT MODE to FH.
Set RT CHAN to MAN or channel 1 thru 6.
Set ECCM fill device select switch to position containing the lockout set.
Set ECCM fill device function switch to ON.
Press LOAD. Display cycles as shown.
Press STO. Display blinks and shows
"STOL" followed by the first digit of the
lockout number. The lockout set is now
stored in RT permanent memory.
* If additional lockout sets are to be loaded,
repeat steps a thru j for each.
Set ECCM fill device function switch to OFF.
Disconnect ECCM fill device from RT connector AUDIFILL.
m. Set RT switches as needed for normal operation.
3-3