TM 11-5820-890-30-4
4-46. REPLACEMENT OF J10 CONNECTOR.
Tools:
Cross tip screwdriver
Flat tip screwdriver
Torque screwdriver
Soldering kit
1-1/16-inch socket
Socket wrench
Torque wrench
Expendable Supplies:
Cotton swabs
Solder
Alcohol
References:
Paragraph 4-40 for removal and installation of bottom access cover.
ITEM
ACTION
REMARKS
REMOVAL
a. Bottom access
Remove and retain.
cover (13)
b. Protective cap (24)
Remove from defective J10 connector.
d. Wires
c. J10 connector (23)
Using 1-1/16-inch socket and socket
wrench, remove nut and protective cap
retainer from defective J10 connector.
Discard nut and retain protective cap
retainer. Push J10 connector through
bottom of power supply chassis.
Remove insulation sleeving. Using
soldering kit, tag and desolder wires
from defective J10 connector. Discard
J10 connector.
INSTALLATION
e. Wires
f.
J10 connector
(23)
g. Protective cap (24)
h. Bottom access
cover (13)
Position tagged wires to replacement J10
connector. Using soldering kit, solder
tagged wires to replacement J10
connector. Remove wire tags and slide
insulation sleeving over solder joints.
Position J10 connector (23) to power
supply chassis (15). Using 1-1/16-inch
socket and torque wrench, torque nut
securing protective cap retainer and nut
to 68 to 72 in-lb.
Install on replacement J10 connector.
Install retained bottom cover (13) on
power supply chassis (16).
See figure 4-10.
Refer to paragraph 4-40 for
removal procedures.
See figure 4-11.
A replacement nut is
supplied with replacement
connector.
These were removed in
step d. Before and after
soldering, clean solder
joints with alcohol and
cotton swabs.
These were removed in
step c.
Refer to paragraph 4-40 for
installation procedures.
4-153