TM 11-5820-890-10-1
MONITORING FH SYNC TIME OF OTHER FH NETS
Monitoring FH Sync Time. This procedure allows you to check the FH sync time
of other active FH nets in your RT (other active FH nets are those you have entered
besides your own net). Monitoring FH sync time is useful when you suspect that you
have dropped out of another net and you wish to check the time of that net. If you
find that your time is out of sync with the other active net, you may perform passive
late net entry. If late net entry is not successful, perform CUE and ERF procedure.
Checking FH Sync Time.
a. Press TIME.
b.
Enter number of channel for other active FH net (display will change to show
other nets FH sync time).
l
To view your RT base clock FH sync time, set CHAN to MAN (or empty
channel); then press TIME as needed.
COMSEC KEY LOADING (REMOTE FILL)
LOADING COMSEC KEY (REMOTE FILL). In this procedure a COMSEC key (TEK)
.is transmitted from net control station to net member stations. Refer to the following
illustration as needed.
KYX-15 Connected to RT
NOTE
Steps marked NCS are done only by the net control station. Steps
marked member are done only by the net member stations. Mem-
bers must have a KEK loaded (in channel 6) in their RT to be able
to receive a remote fill.
3-16