TM 11-5820-890-10-3
LOCAL FILLS
TRANSEC VARIABLE. Loading TRANSEC Variable (local fill). Only one TRANSEC variable is needed in the RT. It
must be stored in the permanent memory. A second TRANSEC variable may be loaded into the HM and stored for use at
a later time (when a TRANSEC variable change is needed).
a.
Make sure that the ECCM fill device is loaded.
If the ECCM fill device needs to be filled, refer to ECCM fill device section in Chapter 4 of this manual.
b.
Set ECCM fill device function switch to OFF.
CAUTION
DO NOT CONNECT FILL DEVICE DIRECTLY TO RADIO AUD/FILL CON-
NECTOR. CONNECTOR DAMAGE MAY OCCUR IF FILL CABLE IS NOT
USED.
c
Connect ECCM fill device to RT connector AUDIFILL using fill cable.
d
Set RT FCTN to LD-V.
e
Set RT MODE to FH, CHAN to MAN or channels 1 thru 6.
f
Set ECCM fill device select switch to T1 or T2 (depending on which TRANSEC variable needs to be loaded).
3-3