TM 11-5820-890-30-4
15-13. REPLACEMENT OF FL1 FILTER. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
i.
j.
k.
l.
m.
n.
o.
Filter mounting plate (22)
Hex nut (27) and
Iockwaaher (26)
FL1 filter (20) terminals
FL1 filter (20) wires
Filter mounting plate (22)
Three screws (25),
lockwashers (24),
and flat washers (23)
Eight screws(5)
and Iockwashers (6)
Install FL1 filter (20) in mounting hole
of filter mounting plate (22).
Use 5/16-inch wrench. Install and hand
tighten hex nut (27) and Iockwasher (26)
securing FL1 fitter (20) to filter mounting
plate (22).
Using cotton swabs and alcohol, clean
both terminals on FL1 filter (20).
Use soldering kit. Solder wires to correct
terminals of FL1 filter (20).
Position filter mounting plate (22) in
connector case (12).
Use cross tip screwdriver. Install and
tighten three screws (25), Iockwashers
(24), and flat washers (23) securing
filter mounting plate (22) to connector
case (12).
Use cross tip screwdriver. Install and
hand tighten eight screws (5) and
but will not tighten, refer
Iockwashers (6) securing access
to paragraph 15-16 for
cover (1) to connector case (12).
replacement of its threaded
Use torque screwdriver. Torque
screw insert (if present).
screws to 8 to 10 in-lb.
If a tapped hole is defec-
tive, refer to paragraph
15-10 for replacement of
the connector case. (12).
15-14. REPLACEMENT OF FL2 FILTER.
Tools:
Cross tip screwdriver
3/8-inch wrench
Expendable supplies:
Solder
Alcohol
References:
Paragraph
Soldering kit
Cotton swabs
15-10 for removal and installation of connector case.
If a screw is not stripped
but will not tighten, inspect
its tapped hole. If the tap-
ped hole is defective, refer
to paragraph 15-10 for re-
placement of connector
case (12).
If a screw is not stripped
15-14