TM 11-5820-890-30-4
15-14. REPLACEMENT OF FL2 FILTER. Continued
ITEM
ACTION
REMARKS
INSTALLATION continued
l.
FL1 filter (20) and
Use soldering kit. Solder wires to cor-
FL2 filter (21) wires
rect terminals of FL2 filter (21) and
top terminal on FL1 filter (20).
m. Filter mounting plate (22)
Position filter mounting plate (22) in
connector case (12).
n. Three screws (25),
Use cross tip screwdriver. Install and
Iockwashers (24),
tighten three screws (25), Iockwashers
and flat washers (23)
(24), and flat washers (23) securing
filter mounting plate (22) to connector
case (12).
o.
Eight screws (5)
Use cross tip screwdriver. Install and
and Iockwashers (6)
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover(l) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
15-15. REPLACEMENT OF WIRING.
Tools:
Diagonal cutting pliers
Wire stripper
Expendable supplies:
Solder
Alcohol
Soldering kit
Cotton swabs
References:
Paragraph 15-12 for removal and installation of J5 connector.
If a screw is not stripped
but will not tighten, inspect
its tapped hole. If the tap-
ped hole is defective, refer
to paragraph 15-10 for re-
placement of connector
case (12).
If a screw is not stripped
but will not tighten, refer
to paragraph 15-16 for
replacement of its threaded
screw insert (if present).
If a tapped hole is defec-
tive, refer to paragraph
15-10 for replacement of
the connector case. (12).
ITEM
ACTION
REMARKS
REMOVAL
a. Eight screws (5) and
Use cross tip screwdriver. Remove and
Inspect each screw and its
Iockwashers (6)
inspect eight screws (5) and lockwash-
threaded screw insert (if
era (6) securing access cover (1) to
present) to determine if
connector case (12). If damaged,.
any is defective. If a screw
obtain replacement. Lay access cover
is stripped, do not replace
to one side. See figure 15-3.
its threaded screw insert.
If the holes are tapped,
there will be no threaded
screw insert.
15-16