TM 11-5820-890-30-4
7-10. REPLACEMENT OF CONNECTOR CASE. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
p.
q.
r.
Screw (19) and Iockwasher
(18)
J5 connector (16)
J5 connector (16) wires
s. Tiedown strap (13)
t.
Neoprene gasket
u.
v.
Two screws (14)
(four screws for older
versions) and guide
pin (15)
Eight screws (5)
and Iockwashers (6)
Use cross tip screwdriver. Install and
hand tighten screw (19) and Iockwasher
(18) securing E1 terminal lug (17) next
to filter mounting plate (22) or on
remaining hole of FILTER EMI-CCA.
Position J5 connector (16) next to mount-
ing hole in connector case (12).
Use soldering kit. Solder wires to correct
terminals of connector.
Replace tiedown strap (13) if removed.
Coat the neoprene gasket of J5 connec-
tor (16) with silicone compound, and
place the connector in mounting hole of
connector case (12).
Use flat tip (or cross tip) screwdriver
and adjustable wrench. Install and hand
tighten two (or four) screws (14) and
guide pin (15) securing J5 connector
(16) to connector case (12).
Use cross tip screwdriver. Install and
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover (1) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
NOTE
Ensure each wire is placed
through mounting hole in
connector case (12).
Before and after soldering
clean wires and terminals
with cotton swabs and
alcohol.
7-9