TM 11-5820-890-30-4
7-13. REPLACEMENT OF FL1 FILTER. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
i.
Filter mounting plate (22)
j.
Hex nut (27) and
Iockwasher (26)
k. FL1 filter (20) terminals
l.
FL1 filter (20) wires
m. Filter mounting plate (22)
n. Three screws (25),
Iockwashers (24),
and flat washers (23)
Install FL1 filter (20) in mounting
hole of filter mounting plate (22).
Use 5/16-inch wrench. Install and
hand tighten hex nut (27) and lock-
washer (26) securing FL1 filter (20)
to filter mounting plate (22).
Using cotton swabs and alcohol, clean
both terminals on FL1 filter (20).
Use soldering kit. Solder wires to correct
terminals of FL1 filter (20).
Position filter mounting plate (22) in con-
nector case (12).
Use cross tip screwdriver. Install and
If a screw is not stripped
tighten three screws (25), Iockwashers
but will not tighten, inspect
(24), and flat washers (23) securing
its tapped hole. If the tap-
filter mounting plate (22) to connector
ped hole is defective, refer
case (12).
to paragraph 7-10 for re-
placement of connector
O . Eight screws (5)
Use cross tip screwdriver. Install and
and Iockwashers (6)
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover (1) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
7-14. REPLACEMENT OF FL2 FILTER.
Tools:
Cross tip screwdriver
Soldering kit
3/8-inch wrench
Expendable supplies:
Solder
Alcohol
Cotton swabs
References:
Paragraph 7-10 for removal and installation of connector case.
Paragraph 7-16 for removal and installation of threaded screw inserts.
case (12).
If a screw is not stripped
but will not tighten, refer
to paragraph 7-16 for re-
placement of its threaded
screw insert (if present).
If a tapped hole is defec-
tive, refer to paragraph
7-10 for replacement of
the connector case. (12).
7-14