TM 11-5820-890-30-4
7-11. REPLACEMENT OF J1, J2, J3, OR J4 CONNECTOR. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
f. Connector terminals
Use soldering kit. Solder wires to correct
NOTE
terminals of connector. If necessary,
Ensure each wire
slide insulation sleeving down over
Iation sleeving on
connection, and apply heat to it until it
essary, and each
has insu-
it if nec-
wire is
shrinks tight around the connection.
placed through mounting
hole in connector case
(12). While soldering wires,
attach heat sink to bare
wire between insulation
sleeving and terminal.
Before and after soldering,
clean wires and terminals
with cotton swabs and
alcohol.
g. Tiedown straps (13)
Replace any tiedown straps (13) that
were removed.
h. Eight screws (5)
Use cross tip screwdriver. Install and
and Iockwashers (6)
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover (1) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
If a screw is not stripped
but will not tighten, refer
to paragraph 7-16 for re-
placement of its threaded
screw insert (if present).
If a tapped hole is defec-
tive, refer to paragraph
7-10 for replacement of
the connector case. (12).
7-12. REPLACEMENT OF J5 CONNECTOR.
Tools:
Flat tip screwdriver
Soldering kit
Adjustable wrench
Expendable supplies:
Silicone compound
Cotton swabs
Alcohol
Solder
References:
Paragraph 7-16 for removal and installation of threaded screw inserts.
ITEM
ACTION
REMARKS
REMOVAL
a. Electrical connector
assembly (13A1)
Set on work surface with J5 connector
(16) toward you. See figure 7-2.
7-11