TM 11-5820-890-30-4
13-41. REPLACEMENT OF WIRING IN POWER SUPPLY ADAPTER CHASSIS (8A2). Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
k.
l.
m.
n.
Terminal post
Use soldering kit and long nose pliers.
Before and after soldering,
Wrap and solder end of replacement
clean wires and terminal
wire on terminal post.
post with alcohol and
cotton swabs.
Tiedown straps (11)
Install replacement tiedown straps on
wiring harness, and remove wire tags.
Rear access cover (2)
Position replacement rear access cover
on the power supply adapter chassis.
See figure 13-7.
Use flat tip screwdriver. Install and hand
screws (11)
tighten the 12 captive screws securing
the rear access cover on the chassis.
Use torque screwdriver. Torque screws
to 8 to 10 in-lb.
Section V. PREPARATION FOR STORAGE OR SHIPMENT
13-42. GENERAL INFORMATION.
a.
Pack the power supply adapter and any removed modules in approved shipping containers.
b. All modules must be shipped enclosed in material that provides protection from static electricity. See
the following paragraph.
13-43. PACKING STATIC SENSITIVE MODULES.
The following steps should be followed when packing a static sensitive module for storage or shipment.
CAUTION
STATIC SENSITIVE
To avoid damaging static sensitive modules, use an antistatic pad on the work surface and wear
a grounded wrist strap when handling the module.
ITEM
ACTION
REMARKS
a. Module (1)
Place inside antistatic bag (2) or inside
antistatic wrapping material (3). See
figure 13-12.
b. Antistatic package (4)
Seal with adhesive tape. Attach
sensitive electronic devices unit
pack label (5).
c. Antistatic package (4)
Place inside approved shipping container (6).
Attach sensitive electronic devices
intermediate pack label (7).
13-76