TM 11-5820-890-30-4
8-15. REPLACEMENT OF TWO-WIRE TRANSIENT PROTECTION CCA. Continued
ITEM
ACTION
REMARKS
INSTALLATION
h. Two-wire transient
Position replacement two-wire transient pro-
protection CCA (26)
tection CCA to retained access cover (27).
i.
Four screws (9), flat
Use cross tip screwdriver. Install four re-
washers (7), and lock-
tained screws, flat washers, and lock-
washers (8)
j.
Bus wires
k. Wires
l. Access cover (27)
8-16. REPLACEMENT
Tools:
Soldering kit
Soldering aid
Heat sink
Expendable Supplies:
Solder
washers securing replacement two-wire
transient protection CCA (26) to access
cover (27).
Position retained bus wires from E4 to
binding post (28) and E5 to binding post
(28). Use soldering kit. Solder bus wires
to binding posts (28).
Use soldering kit. Solder three tagged
wires to E1 thru E3 of replacement two-
wire transient protection CCA (26).
Position access cover to battery box case
(15). Use torque screwdriver. Tighten five
captive screws (31 ) securing access cov-
These were removed in
step e.
NOTE
Before and after soldering,
clean wires and solder
joints with alcohol and
cotton swabs.
NOTE
Before and after soldering,
clean wires and solder
joints with alcohol and
cotton swabs.
er to battery box case (15). Torque screws
to 5 in-lb.
OF ACCESS COVER.
5/16-inch open end wrench
Cross tip screwdriver
5/16-inch socket
Fiat tip screwdriver
Torque wrench
Torque screwdriver
Alcohol
Cotton swabs
ITEM
ACTION
REMARKS
REMOVAL
a. Access cover (27)
Use fiat tip screwdriver. Fully loosen
five captive screws (31) securing access
cover to battery box case (15). Remove
to allow desoldering.
b. Two-wire transient protec-
Use soldering kit. Tag and desolder three
tion CCA (26)
wires from terminals of two-wire transient
protection CCA.
8-12