TM 11-5820-890-10-3
REMOTE FILL OF TRANSEC KEY
NCS
MEMBER
1.
Load new TRANSEC Key into
1.
No action required.
KYX-15 using ECCM fill device or
generate new TRANSEC Key (if
authorized).
2.
Perform NCS TRANSEC Key local
2.
No action required.
fill:
a)
Connect KYX-15 to RT.
b)
Set RT FCTN to LD-V.
c)
Set KYX-15 MODE to LD and
new TRANSEC ADDRESS switch
TO ON.
d)
Press RT HLd button, and
note display reading "HLd t".
e)
Set KYX-15 address switch
to OFF; then remove fill cable
from RT and connect to KY-57
FILL connector.
3.
Make sure that net is operating in
3.
Wait for NCS instructions; remain
secure mode; then alert the net for
In secure (C) mode.
TRANSEC Key Remote Fill.
4.
Provide guidance to net members:
4.
(Follow NCS directions):
a)
Connect RT FILL to KY-57 FILL
using fill cable.
b)
Set RT FCTN to LD-V.
c)
Set KY-57 FILL SELECTOR
switch to 5 and MODE to RV.
d)
Set KY-57 FILL SELECTOR
switch to empty position.
e)
Stand by.
5.
Send TRANSEC Key Remote Fill to
5.
Continue to stand by.
net:
a)
Set KYX-15 MODE to MK.
a)
No action required.
b)
Set KYX-15 ADDRESS switch
b)
No action required.
to ON.
c)
Press KYX-15 INITIATE switch.
c)
Watch as SIG display flutters;
then wait 2 seconds and press
RT HLd button and set KY-57
MODE to C.
d)
Confirm member's reception
d)
Press Sto/ENT. and note display
of TRANSEC Key; then press
reading of "Sto t".
Sto/ENT.
e)
Confirm net communication
e)
Acknowledge.
using new TRANSEC Key.
6.
TRANSEC Key Remote Fill com-
6.
TRANSEC Key Remote Fill com-
plete.
plete.
3-20