TM 11-5820-890-10-3REMOTE FILL OF TRANSEC KEYNCS MEMBER1.Load new TRANSEC Key into1.No action required.KYX-15 using ECCM fill device orgenerate new TRANSEC Key (ifauthorized).2.Perform NCS TRANSEC Key local2.No action required.fill:a)Connect KYX-15 to RT.b)Set RT FCTN to LD-V.c)Set KYX-15 MODE to LD andnew TRANSEC ADDRESS switchTO ON.d)Press RT H•Ld button, andnote display reading "HLd t".e)Set KYX-15 address switchto OFF; then remove fill cablefrom RT and connect to KY-57FILL connector.3.Make sure that net is operating in3.Wait for NCS instructions; remainsecure mode; then alert the net forIn secure (C) mode.TRANSEC Key Remote Fill.4.Provide guidance to net members:4.(Follow NCS directions):a)Connect RT FILL to KY-57 FILLusing fill cable.b)Set RT FCTN to LD-V.c)Set KY-57 FILL SELECTORswitch to 5 and MODE to RV.d)Set KY-57 FILL SELECTORswitch to empty position.e)Stand by.5.Send TRANSEC Key Remote Fill to5.Continue to stand by.net:a)Set KYX-15 MODE to MK.a)No action required.b)Set KYX-15 ADDRESS switchb)No action required.to ON.c)Press KYX-15 INITIATE switch.c)Watch as SIG display flutters;then wait 2 seconds and pressRT H•Ld button and set KY-57MODE to C.d)Confirm member's receptiond)Press Sto/ENT. and note displayof TRANSEC Key; then pressreading of "Sto t".Sto/ENT.e)Confirm net communicatione)Acknowledge.using new TRANSEC Key.6.TRANSEC Key Remote Fill com-6.TRANSEC Key Remote Fill com-plete.plete.3-20
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business